1.1 This document
— amplifies the general principles for designing experiments for the numerical estimation of the precision of measurement methods by means of a collaborative interlaboratory experiment;
— provides a detailed practical description of the basic method for routine use in estimating the precision of measurement methods;
— provides guidance to all personnel concerned with designing, performing or analysing the results of the tests for estimating precision.
NOTE Modifications to this basic method for particular purposes are given in other parts of ISO 5725.
1.2 It is concerned exclusively with measurement methods which yield measurements on a continuous scale and give a single value as the test result, although this single value can be the outcome of a calculation from a set of observations.
1.3 It assumes that in the design and performance of the precision experiment, all the principles as laid down in ISO 5725-1 are observed. The basic method uses the same number of test results in each laboratory, with each laboratory analysing the same levels of test sample; i.e. a balanced uniform-level experiment. The basic method applies to procedures that have been standardized and are in regular use in a number of laboratories.
1.4 The statistical model of ISO 5725-1:1994, Clause 5, is accepted as a suitable basis for the interpretation and analysis of the test results, the distribution of which is approximately normal.
1.5 The basic method, as described in this document, (usually) estimates the precision of a measurement method:
a) when it is required to determine the repeatability and reproducibility standard deviations as defined in ISO 5725-1;
b) when the materials to be used are homogeneous, or when the effects of heterogeneity can be included in the precision values; and
c) when the use of a balanced uniform-level layout is acceptable.
1.6 The same approach can be used to make a preliminary estimate of precision for measurement methods which have not reached standardization or are not in routine use.

  • Standard
    69 pages
    English language
    sale 15% off
  • Standard
    75 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    73 pages
    French language
    sale 15% off

1.1 This document
— specifies basic methods for estimating the bias of a measurement method and the laboratory bias when a measurement method is applied;
— provides a practical approach of a basic method for routine use in estimating the bias of measurement methods and laboratory bias;
— provides a brief guidance to all personnel concerned with designing, performing or analysing the results of the measurements for estimating bias.
1.2 It is concerned exclusively with measurement methods which yield measurements on a continuous scale and give a single value as the measurement result, although the single value can be the outcome of a calculation from a set of observations.
1.3 This document applies when the measurement method has been standardized and all measurements are carried out according to that measurement method.
NOTE In ISO/IEC Guide 99:2007(VIM), "measurement procedure" (2.6) is an analogous term related to the term "measurement method" used in this document.
1.4 This document applies only if an accepted reference value can be established to substitute the true value by using the value, for example:
— of a suitable reference material;
— of a suitable measurement standard;
— referring to a suitable measurement method;
— of a suitable prepared known sample.
1.5 This document applies only to the cases where it is sufficient to estimate bias on one property at a time. It is not applicable if the bias in the measurement of one property is affected by the level of any other property (i.e. it does not consider interferences by any influencing quantity). Comparison of the trueness of two-measurement methods is considered in ISO 5725-6.

  • Standard
    31 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    26 pages
    English language
    sale 15% off
  • Standard
    27 pages
    French language
    sale 15% off

This document specifies a method for the enumeration of Pseudomonas aeruginosa in water. The
method is based on the growth of target organisms in a liquid medium and calculation of the most
probable number (MPN) of organisms by reference to MPN tables.
This document is applicable to a range of types of water. For example, hospital waters, drinking water
and non‐carbonated bottled waters intended for human consumption, groundwater, swimming pool
and spa pool waters including those containing high background counts of heterotrophic bacteria.
This document does not apply to carbonated bottled waters, flavoured bottle waters, cooling tower
waters or marine waters, for which the method has not been validated. These waters are, therefore,
outside the scope of this document. Laboratories can employ the method presented in this document
for these matrices by undertaking appropriate validation of performance of this method prior to use.
The test is based on a bacterial enzyme detection technology that signals the presence of P. aeruginosa
through the hydrolysis of a 7‐amino‐4‐methylcoumarin aminopeptidase substrate present in a special
reagent. P. aeruginosa cells rapidly grow and reproduce using the rich supply of amino acids, vitamins
and other nutrients present in the reagent. Actively growing strains of P. aeruginosa have an enzyme
that cleaves the 7‐amido‐coumarin aminopeptidase substrate releasing a product which fluoresces
under ultraviolet (UV) light. The test described in this document provides a confirmed result within
24 h with no requirement for further confirmation of positive wells.

  • Standard
    122 pages
    English language
    sale 15% off
  • Standard
    127 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    134 pages
    French language
    sale 15% off
  • Standard
    134 pages
    French language
    sale 15% off

This document specifies the following semi-quantitative methods for the assessment of transparency
of waters:
a) measurement of visual range using the transparency testing tube (applicable to transparent and
slightly cloudy water), see Clause 4;
b) measurement of visual range in the upper water layers using the transparency testing disc
(especially applicable to surface, bathing water, waste water and often used in marine monitoring),
see 5.1;
c) measurement of visibility by divers in a destined depth, see 5.2.
NOTE The quantitative methods using optical turbidimeters or nephelometers are described in ISO 7027-1.

  • Standard
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO/IEC 17025:2017 specifies the general requirements for the competence, impartiality and consistent operation of laboratories.
ISO/IEC 17025:2017 is applicable to all organizations performing laboratory activities, regardless of the number of personnel.
Laboratory customers, regulatory authorities, organizations and schemes using peer-assessment, accreditation bodies, and others use ISO/IEC 17025:2017 in confirming or recognizing the competence of laboratories.

  • Standard
    39 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard – translation
    51 pages
    Slovenian and English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    36 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This International Standard specifies a method for the enumeration of vegetative cells and spores of Clostridium perfringens by the membrane filtration method in samples of water intended for human consumption. However, the method can be applied to all types of water samples provided they do not contain particulate or colloidal matter that interferes with filtration.

  • Standard
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of ISO 7027 specifies two quantitative methods using optical turbidimeters or nephelometers
for the determination of turbidity of water:
a) nephelometry, procedure for measurement of diffuse radiation, applicable to water of low turbidity
(for example drinking water);
b) turbidimetry, procedure for measurement of the attenuation of a radiant flux, more applicable to
highly turbid waters (for example waste waters or other cloudy waters).
Turbidities measured according to the first method are presented as nephelometric turbidity units
(NTU). The results typically range between <0,05 NTU and 400 NTU. Depending on the instrument
design, it can also be applicable to waters of higher turbidity. There is numerical equivalence of the
units NTU and formazin nephelometric unit (FNU).
Turbidity measured by the second method is expressed in formazin attenuation units (FAU), results
typically range between 40 FAU and 4 000 FAU.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of ISO 9308 specifies a method for the enumeration of Escherichia coli (E. coli) and coliform
bacteria. The method is based on membrane filtration, subsequent culture on a chromogenic coliform
agar medium, and calculation of the number of target organisms in the sample. Due to the low selectivity
of the differential agar medium, background growth can interfere with the reliable enumeration of
E. coli and coliform bacteria, for example, in surface waters or shallow well waters. This method is not
suitable for these types of water.
This part of ISO 9308 is especially suitable for waters with low bacterial numbers that will cause less
than 100 total colonies on chromogenic coliform agar (CCA). These may be drinking water, disinfected
pool water, or finished water from drinking water treatment plants.
Some strains of E. coli which are β-D-glucuronidase negative, such as Escherichia coli O157, will not be
detected as E. coli. As they are β-D-galactosidase positive, they will appear as coliform bacteria on this
chromogenic agar.

  • Standard
    18 pages
    English language
    sale 10% off
    e-Library read for
    1 day

EN ISO 9308-2 specifies a method for the enumeration of E. coli and coliform bacteria in water. The method is based on the growth of target organisms in a liquid medium and calculation of the “Most Probable Number” (MPN) of organisms by reference to MPN tables. This method can be applied to all types of water, including those containing an appreciable amount of suspended matter and high background counts of heterotrophic bacteria. However, it must not be used for the enumeration of coliform bacteria in marine water. When using for the enumeration of E. coli in marine waters, a 1  10 dilution in sterile water is typically required, although the method has been shown to work well with some marine waters that have a lower than normal concentration of salts. In the absence of data to support the use of the method without dilution, a 1  10 dilution is used. This method relies upon the detection of E. coli based upon expression of the enzyme β-D-glucuronidase and consequently does not detect many of the enterohaemorhagic strains of E. coli, which do not typically express this enzyme. Additionally, there are a small number of other E. coli strains that do not express β-D-glucuronidase. The choice of tests used in the detection and confirmation of the coliform group of bacteria, including E. coli, can be regarded as part of a continuous sequence. The extent of confirmation with a particular sample depends partly on the nature of the water and partly on the reasons for the examination. The test described in this part of ISO 9308 provides a confirmed result with no requirement for further confirmation of positive wells.

  • Standard
    54 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard describes the principles of a risk management approach to improve the integrity of the drinking water supply system. This European Standard addresses all entities and stakeholders sharing responsibility in the provision of safe drinking water throughout the entire supply chain from the source to the point of use.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of ISO 5667 establishes principles to be applied to the techniques of sampling water intended for human consumption. For the purposes of this part of ISO 5667, water intended for human consumption comprises: a) all water either in its original state or after treatment, intended for drinking, cooking, food preparation, or other domestic purposes, regardless of its origin, plus b) all water used in any production undertaking for the manufacture, processing, preservation or marketing of products or substances intended for human consumption unless the competent national authorities are satisfied that the quality of the water cannot affect the wholesomeness of the foodstuff in its finished form. The guidance given in this part of ISO 5667 is confined to those circumstances where water is drawn from municipal or similar distribution systems (including individual systems) where prior treatment and/or quality assessment has resulted in the water being classified as suitable for drinking or potable process purposes. Specifically, this part of ISO 5667 is applicable to water that is in continuous supply relative to any stage of use up to and including the point of consumption in a distribution system. This includes distribution within large buildings in which additional water quality management might be applicable. This part of ISO 5667 is also applicable to sampling situations that can arise relative to the investigation of system defects or emergency situations where the safety of sampling operatives is not compromised. This part of ISO 5667 does not provide guidance for water sources or for products generated by using drinking water. The followings items are examples of cases not addressed by the present document: the sampling of source water, for example groundwater and surface water impoundments; sampling of drinking water supplies derived from non-continuous sources (for example, from road tankers); sampling of bulk storage of water on airplanes, trains and ships; the sampling of beverage products (including bottled waters) or food containing potable water used in its preparation; sampling of drink vending machines that dispense unsealed cups of drinks.

  • Standard
    18 pages
    English language
    sale 15% off
  • Standard
    17 pages
    English language
    sale 15% off
  • Standard
    23 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This International Standard provides guidance on planning water sampling regimes, on sampling procedures for microbiological analysis and on transport, handling and storage of samples until analysis begins. It focuses on sampling for microbiological investigations. General information in respect to the sampling from distinct water bodies is given in the respective parts of ISO 5667.

  • Standard
    25 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Specifies four intermediate measures due to changes in observation conditions (time, calibration, operator and equipment) within a laboratory. These intermediate measures can be established by an experiment within a specific laboratory or by an interlaboratory experiment. Furthermore, discusses the implications of the definitions of intermediate precision measures, presents guidance on the interpretation and application of the estimates of intermediate precision measures in practical situations, discusses the connections between trueness and measurement conditions.

  • Standard
    25 pages
    English language
    sale 15% off
  • Standard
    25 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    25 pages
    French language
    sale 15% off
  • Standard
    25 pages
    French language
    sale 15% off

The purpose is to outline the general principles to be understood when assessing accuracy (trueness and precision) of measurement methods and results, and in applications, and to establish practical estimations of the various measures by experiment. Is concerned exclusively with measurement methods which yield measurements on a continuous scale and give a single value as the test result. May be applied to a very wide range of materials, including liquids, powders and solid objects, manufactured or naturally occurring, provided that due consideration is given to any heterogeneity of the material.

  • Standard
    17 pages
    English language
    sale 15% off
  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    18 pages
    French language
    sale 15% off
  • Standard
    18 pages
    French language
    sale 15% off

The purpose is to give some indications of the way in which accuracy data can be used in various practical situations by: giving a standard method of calculating the repeatability limit, the reproducibility limit and other limits, providing a way of checking the acceptability of test results obtained under repeatability or reproducibility conditions, describing how to assess the stability of results within a laboratory over a period of time, describing how to assess whether a given laboratory is able to use a given standard measurement method in a satisfactory way, describing how to compare alternative measurement methods.

  • Standard
    41 pages
    English language
    sale 15% off
  • Standard
    41 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    41 pages
    French language
    sale 15% off
  • Standard
    41 pages
    French language
    sale 15% off
  • Standard
    56 pages
    English language
    sale 15% off
  • Standard
    56 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    57 pages
    French language
    sale 15% off

Migrated from Progress Sheet (TC Comment) (2000-07-10): TC 230 Res. 87: // approval procedure on the revision of ISO 7899-2:1984. ++ N315: New TD (TA/980915)

  • Standard
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies a method for the enumeration of culturable micro-organisms in water by counting the colonies formed in a nutrient agar culture medium after aerobic incubation at 36 °C and 22 °C. The method is intended to measure the operational efficiency of the treatment process of public drinking water supplies and for general application to all types of water. It is particulary applicable to the examination of water intended for  human consumption, including water in closed containers and to natural mineral waters.

  • Standard
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day

The principle of the method specified is heating a sample in a boiling water-bath with a known amount of potassium permanganate und sulfuric acid for a fixed period time (10 min), reducing part of the permanganate by oxidizable material in the sample and determining the consumed permanganate by addition of an excess of oxalate solution, followed by titration with permanganate. Applies to waters having a cloride ion concentration of less than 300 mg/l. Samples having a permanganate index over 10 mg/l should be diluted before analysis. The lower limit of the optimum range of the test is 0,5 mg/l.