This document specifies a method for determining the pour point of petroleum products by means of automated equipment, in which movement of the test specimen is detected using a step-wise cooling technique. A separate procedure suitable for the determination of the lower pour point of fuel oils, heavy lubricant base stock, and products containing residual fuel components is also described. The procedure described in this document is not suitable for crude oils. Test results from this method are determined in 3 °C testing intervals. NOTE Some equipment can also generate results at 1 °C testing intervals, which is an acceptable alternative procedure, but for which precision and bias have not been determined.

  • Technical specification
    10 pages
    English language
    sale 15% off
  • Draft
    10 pages
    English language
    sale 15% off
  • Draft
    10 pages
    English language
    sale 15% off

This document specifies a method to identify and compare the compositional characteristics of oil
samples. Specifically, it describes the detailed analytical and data processing methods for identifying the
characteristics of spill samples and establishing their correlation to suspected source oils. Even when
samples or data from suspected sources are not available for comparison, establishing the specific nature
(e.g. refined petroleum, crude oil, waste oil, etc.) of the spilled oil still helps to constrain the possible
source(s).
This methodology is restricted to petroleum related products containing a significant proportion of
hydrocarbon-components with a boiling point above 150 °C. Examples are: crude oils, higher boiling
condensates, diesel oils, residual bunker or heavy fuel oils, lubricants, and mixtures of bilge and sludge
samples, as well as distillate fuels and blends. While the specific analytical methods are perhaps not
appropriate for lower boiling oils (e.g. kerosene, jet fuel, or gasoline), the general concepts described in
this methodology, i.e. statistical comparison of weathering-resistant diagnostic ratios, are applicable in
spills involving these kinds of oils.
Paraffin products (e.g. waxes, etc.) are outside the scope of this method because too many compounds
are removed during the production process [37] to correctly distinguish them from each other. However,
the method can be used to identify the type of product involved.
Although not directly intended for identifying oil recovered from groundwater, vegetation,
wildlife/tissues, soil, or sediment matrices, they are not precluded. However, caution is needed as
extractable compounds can be present in these matrices that alter and/or contribute additional
compounds compared to the source sample. If unrecognized, the contribution from the matrix can lead
to false “non-matches”. It is therefore advisable to analyse background sample(s) of the matrix that
appear unoiled.
When analysing “non-oil” matrices additional sample preparation (e.g. clean-up) is often required prior
to analysis and the extent to which the matrix affects the correlation achieved is to be considered.
Whether the method is applicable for a specific matrix depends upon the oil concentration compared to
the “matrix concentration”. In matrices containing high concentrations of oil, a positive match can still be
concluded. In matrices containing lower concentrations of oil, a false “non-match” or an “inconclusive
match” can result from matrix effects. Evaluation of possible matrix effects is beyond the scope of this
document.

  • Standard
    219 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    194 pages
    English language
    sale 10% off
    e-Library read for
    1 day

EN 15522-1 provides guidance on taking and handling samples, that are collected as part of an investigation into the likely source of a crude oil or petroleum product spill into a marine or aquatic environment. Guidance is given on taking samples from both the spill and its potential source.
Mostly, oil sampling is part of legal procedures and has to be treated like any other preservation of evidence (legal sampling). If samples are to be used in connection with legal proceedings, this document should be read in conjunction with any documents issued by the regulatory authorities in the country or countries in question where the spill has occurred.
Taking samples may involve hazardous materials, operations and equipment.
This document is not intended to address all the safety and health aspects associated with the guidance given. It is the responsibility of the user to consult and establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Note: Most countries have special trained teams to take samples on board of ships. As police officer or law enforcer don’t take unnecessary risks and ask assistance from such a team when available.
For the sake of clarity, the word ‘oil’ is used throughout this document. It can equally refer to crude oil, a petroleum product or mixtures of such.

  • Standard
    31 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    29 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a method to identify and compare the compositional characteristics of oil samples. Specifically, it describes the detailed analytical and data processing methods for identifying the characteristics of spill samples and establishing their correlation to suspected source oils. Even when samples or data from suspected sources are not available for comparison, establishing the specific nature (e.g. refined petroleum, crude oil, waste oil, etc.) of the spilled oil still helps to constrain the possible source(s).
This methodology is restricted to petroleum related products containing a significant proportion of hydrocarbon-components with a boiling point above 150 °C. Examples are: crude oils, higher boiling condensates, diesel oils, residual bunker or heavy fuel oils, lubricants, and mixtures of bilge and sludge samples, as well as distillate fuels and blends. While the specific analytical methods are perhaps not appropriate for lower boiling oils (e.g. kerosene, jet fuel, or gasoline), the general concepts described in this methodology, i.e. statistical comparison of weathering-resistant diagnostic ratios, are applicable in spills involving these kinds of oils.
Paraffin based products (e.g. waxes, etc.) are outside the scope of this method because too many compounds are removed during the production process [37]. However, the method can be used to identify the type of product involved.
Although not directly intended for identifying oil recovered from groundwater, vegetation, wildlife/tissues, soil, or sediment matrices, they are not precluded. However, caution is needed as extractable compounds can be present in these matrices that alter and/or contribute additional compounds compared to the source sample. If unrecognized, the contribution from the matrix can lead to false “non-matches”. It is therefore advisable to analyse background sample(s) of the matrix that appear unoiled.
When analysing “non-oil” matrices additional sample preparation (e.g. clean-up) is often required prior to analysis and the extent to which the matrix affects the correlation achieved is to be considered. Whether the method is applicable for a specific matrix depends upon the oil concentration compared to the “matrix concentration”. In matrices containing high concentrations of oil, a positive match can still be concluded. In matrices containing lower concentrations of oil, a false “non-match” or an “inconclusive match” can result from matrix effects. Evaluation of possible matrix effects is beyond the scope of this document.

  • Standard
    219 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    194 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document provides guidance on taking and handling samples related to oil spill identification in legal proceedings. Guidance is given on obtaining samples from both the spill and its potential source.
Preservation of evidence is an essential part of legal procedures and this document presents appropriate oil sampling procedures.
WARNING - The use of this document can involve hazardous materials, operations and equipment.
This document does not purport to address all of the safety problems associated with its use. It is the responsibility of users of this document to take appropriate measures to ensure the safety and health of personnel prior to the application of the standard, and to determine the applicability of any other restrictions for this purpose.
IMPORTANT - Most countries have teams with specialists trained in sampling on board of ships. Do not take unnecessary risks, seek assistance from such teams where available.
NOTE   For the sake of clarity, the word ‘oil’ is used throughout this document. It can equally refer to crude oil, a petroleum product or mixtures of such.

  • Standard
    31 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    29 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the process and methodology for the construction, operation, and maintenance of statistical control charts to assess if a laboratory's execution of a standard test method is in-statistical-control and how to establish and validate the 'in-statistical-control' status.
It specifies control charts that are most appropriate for ISO/TC 28 test methods where the dominant common cause variation is associated with the long term, multiple operator conditions. The control charts specified for determination of in-statistical-control are: individual (I), moving range of 2 (MR2), and either the exponentially weighted moving average (EWMA) or zone-based run rules [similar to Western Electric (WE) run rules[3]] as sensitivity enhancement strategy to support the I-chart.
The procedures in this document have been primarily designed for numerical results obtained from testing of control samples prepared from a homogenous source of petroleum and related products in a manner that preserves the homogeneity of properties of interest between control samples. If the test method permits, a certified reference material (CRM) sample is used as a control sample provided the sample composition is representative of the material being tested and is not a pure compound; if this is done then the laboratory best establishes its own mean for the CRM sample.
This document is applicable to properties of interest that are (known to be) stable over time, and for data sets with sufficient resolution to support validation of the assumption that the data distribution can be approximately represented by the normal (Gaussian) model. Mitigating strategies are suggested for situations where the assumption cannot be validated.

  • Standard
    44 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    37 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document describes three procedures (A, B and C) covering determinations of flash no-flash and flash point.
Rapid equilibrium procedures A and B are applicable to flash no-flash and flash point tests of paints, including water-borne paints, varnishes, binders for paints and varnishes, adhesives, solvents, petroleum products including aviation turbine, diesel and kerosene fuels, fatty acid methyl esters and related products over the temperature range –30 °C to 300 °C. The rapid equilibrium procedures are used to determine whether a product will or will not flash at a specified temperature (flash no-flash procedure A) or the flash point of a sample (procedure B). When used in conjunction with the flash detector (A.1.6), this document is also suitable to determine the flash point of fatty acid methyl esters (FAME). The validity of the precision is given in Table 2.
Non-equilibrium procedure C is applicable to petroleum products including aviation turbine, diesel and kerosine fuels, and related petroleum products, over the temperature range –20 °C to 300 °C. The non-equilibrium procedure is automated to determine the flash point. Precision has been determined over the range 40 °C to 135 °C.
For specifications and regulations, procedures A or B are routinely used (see 10.1.1).

  • Standard
    35 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    33 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document describes three procedures (A, B and C) covering determinations of flash no-flash and flash point.
Rapid equilibrium procedures A and B are applicable to flash no-flash and flash point tests of paints, including water-borne paints, varnishes, binders for paints and varnishes, adhesives, solvents, petroleum products including aviation turbine, diesel and kerosene fuels, fatty acid methyl esters and related products over the temperature range –30 °C to 300 °C. The rapid equilibrium procedures are used to determine whether a product will or will not flash at a specified temperature (flash no-flash procedure A) or the flash point of a sample (procedure B). When used in conjunction with the flash detector (A.1.6), this document is also suitable to determine the flash point of fatty acid methyl esters (FAME). The validity of the precision is given in Table 2.
Non-equilibrium procedure C is applicable to petroleum products including aviation turbine, diesel and kerosine fuels, and related petroleum products, over the temperature range –20 °C to 300 °C. The non-equilibrium procedure is automated to determine the flash point. Precision has been determined over the range 40 °C to 135 °C.
For specifications and regulations, procedures A or B are routinely used (see 10.1.1).

  • Standard
    35 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    33 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document describes three procedures (A, B and C) covering determinations of flash no-flash and flash point. Rapid equilibrium procedures A and B are applicable to flash no-flash and flash point tests of paints, including water-borne paints, varnishes, binders for paints and varnishes, adhesives, solvents, petroleum products including aviation turbine, diesel and kerosene fuels, fatty acid methyl esters and related products over the temperature range –30 °C to 300 °C. The rapid equilibrium procedures are used to determine whether a product will or will not flash at a specified temperature (flash no-flash procedure A) or the flash point of a sample (procedure B). When used in conjunction with the flash detector (A.1.6), this document is also suitable to determine the flash point of fatty acid methyl esters (FAME). The validity of the precision is given in Table 2. Non-equilibrium procedure C is applicable to petroleum products including aviation turbine, diesel and kerosine fuels, and related petroleum products, over the temperature range –20 °C to 300 °C. The non-equilibrium procedure is automated to determine the flash point. Precision has been determined over the range 40 °C to 135 °C. For specifications and regulations, procedures A or B are routinely used (see 10.1.1).

  • Standard
    27 pages
    English language
    sale 15% off
  • Standard
    28 pages
    French language
    sale 15% off
  • Standard
    28 pages
    French language
    sale 15% off
  • Draft
    26 pages
    English language
    sale 15% off
  • Draft
    26 pages
    English language
    sale 15% off
  • Amendment
    7 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    7 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a test method for the determination of the content of mono-aromatic, di-aromatic and tri+-aromatic hydrocarbons in diesel fuels, paraffinic diesel fuels and petroleum distillates.
This document defines two procedures, A and B.
Procedure A is applicable to diesel fuels that may contain fatty acid methyl esters (FAME) up to 30 % (V/V) (as in [1], [2] or [3]) and petroleum distillates in the boiling range from 150 °C to 400 °C (as in [4].
Procedure B is applicable to paraffinic diesel fuels with up to 7 % (V/V) FAME. This procedure does not contain a dilution of the sample in order to determine the low levels of aromatic components in these fuels.
The polycyclic aromatic hydrocarbons content is calculated from the sum of di-aromatic and tri+-aromatic hydrocarbons and the total content of aromatic compounds is calculated from the sum of the individual aromatic hydrocarbon types.
Compounds containing sulfur, nitrogen and oxygen can interfere in the determination; mono-alkenes do not interfere, but conjugated di-alkenes and poly-alkenes, if present, can do so.
NOTE 1   For the purpose of this European Standard, the terms "% (m/m)" and "% (V/V)" are used to represent the mass fraction, µ, and the volume fraction, φ, of a material respectively.
NOTE 2   By convention, the aromatic hydrocarbon types are defined on the basis of their elution characteristics from the specified liquid chromatography column relative to model aromatic compounds. Their quantification is performed using an external calibration with a single aromatic compound for each of them, which may or may not be representative of the aromatics present in the sample. Alternative techniques and test methods may classify and quantify individual aromatic hydrocarbon types differently.
NOTE 3   Backflush is part of laboratory-internal maintenance.
WARNING - The use of this standard can involve hazardous materials, operations and equipment. This standard does not purport to address all of the safety problems associated with its use. It is the responsibility of users of this standard to take appropriate measures to ensure the safety and health of personnel prior to application of the standard, and fulfil statutory and regulatory requirements for this purpose.

  • Standard
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the methodology to determine if a laboratory is in control in the execution of a standard test method. By using statistical control charts and following this document the 'in-statistical-control' status is established and validated. In-statistical-control means the test results produced by the lab on control samples are reasonably consistent with expectation over time; with random variation scattered around a stable expected centre due to common causes only
This document explicitly defines ‘site precision’ conditions as  single apparatus, multi-operators, over a long time horizon. It specifies control charts that are most appropriate for ISO TC28 test methods where the dominant common cause variation is associated with the long term, multiple operator conditions as described by "site precision" conditions. The control charts specified for determination of in-statistical-control are: Individual (I), Moving Range of 2 (MR2), Exponentially Weighted Moving Average (EWMA), and zone-based run rules (commonly known as Western Electric (WE)run rules.
The procedures in this document have been designed specifically for petroleum and petroleum related products, which are normally considered as homogeneous and for test methods which show normality in obtaining their results. However, the procedures described in this document can also be applied to other types of homogeneous products and test methods.

  • Standard
    44 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    37 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a test method for the determination of the content of mono-aromatic, di-aromatic and tri+-aromatic hydrocarbons in diesel fuels, paraffinic diesel fuels and petroleum distillates.
This document defines two procedures, A and B.
Procedure A is applicable to diesel fuels that may contain fatty acid methyl esters (FAME) up to 30 % (V/V) (as in [1], [2] or [3]) and petroleum distillates in the boiling range from 150 °C to 400 °C (as in [4].
Procedure B is applicable to paraffinic diesel fuels with up to 7 % (V/V) FAME. This procedure does not contain a dilution of the sample in order to determine the low levels of aromatic components in these fuels.
The polycyclic aromatic hydrocarbons content is calculated from the sum of di-aromatic and tri+-aromatic hydrocarbons and the total content of aromatic compounds is calculated from the sum of the individual aromatic hydrocarbon types.
Compounds containing sulfur, nitrogen and oxygen can interfere in the determination; mono-alkenes do not interfere, but conjugated di-alkenes and poly-alkenes, if present, can do so.
NOTE 1   For the purpose of this European Standard, the terms "% (m/m)" and "% (V/V)" are used to represent the mass fraction, µ, and the volume fraction, φ, of a material respectively.
NOTE 2   By convention, the aromatic hydrocarbon types are defined on the basis of their elution characteristics from the specified liquid chromatography column relative to model aromatic compounds. Their quantification is performed using an external calibration with a single aromatic compound for each of them, which may or may not be representative of the aromatics present in the sample. Alternative techniques and test methods may classify and quantify individual aromatic hydrocarbon types differently.
NOTE 3   Backflush is part of laboratory-internal maintenance.
WARNING - The use of this standard can involve hazardous materials, operations and equipment. This standard does not purport to address all of the safety problems associated with its use. It is the responsibility of users of this standard to take appropriate measures to ensure the safety and health of personnel prior to application of the standard, and fulfil statutory and regulatory requirements for this purpose.

  • Standard
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    1 page
    English language
    sale 15% off
  • Standard
    2 pages
    French language
    sale 15% off
  • Standard
    2 pages
    French language
    sale 15% off

This document specifies a fluorescent indicator adsorption method for the determination of hydrocarbon types over the concentration ranges from 5 % (V/V) to 99 % (V/V) aromatic hydrocarbons, 0,3 % (V/V) to 55 % (V/V) olefins, and 1 % (V/V) to 95 % (V/V) saturated hydrocarbons in petroleum fractions that distil below 315 °C. This method can apply to concentrations outside these ranges, but the precision has not been determined.
When samples containing oxygenated blending components are analysed, the hydrocarbon type results can be reported on an oxygenate-free basis or, when the oxygenate content is known, the results can be corrected to a total-sample basis.
This test method is applicable to full boiling range products. Cooperative data have established that the precision statement does not apply to petroleum fractions with narrow boiling ranges near the 315 °C limit. Such samples are not eluted properly, and results are erratic.
It does not apply to samples containing dark-coloured components that interfere with reading the chromatographic bands that cannot be analysed.
NOTE 1   The oxygenated blending components methanol, ethanol, tert-butyl methyl ether (MTBE), methyl tert-pentyl ether (TAME) and tert-butyl ethyl ether (ETBE) do not interfere with the determination of hydrocarbon types at concentrations normally found in commercial petroleum blends. These oxygenated compounds are not detected since they elute with the alcohol desorbent. The effects of other oxygenated compounds are individually verified.
NOTE 2   For the purposes of this document, the terms “% (m/m)” and “% (V/V)” are used to represent respectively the mass fraction and the volume fraction.
WARNING — The use of this document can involve hazardous materials, operations and equipment. This document does not purport to address all of the safety problems associated with its use. It is the responsibility of the user of this document to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  • Standard
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard describes a method for the determination of the boiling range distribution of petroleum products by capillary gas chromatography using flame ionization detection. The standard is applicable to stabilized crude oils and for the boiling range distribution and the recovery up to and including n-nonane. A stabilized crude oil is defined as having a Reid Vapour Pressure equivalent to or less than 82,7 kPa as determined by IP 481 [3].
NOTE   For the purposes of this European Standard, the terms “% (m/m)” and “% (V/V)” are used to represent respectively the mass fraction, ω, and the volume fraction, φ.
WARNING —The use of this European Standard may involve hazardous materials, operations and equipment. This European Standard does not purport to address all of the safety problems associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use.

  • Standard
    31 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    30 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the gas chromatographic (GC) method for the determination of saturated, olefinic and aromatic hydrocarbons in automotive motor gasoline and ethanol (E85) automotive fuel. Additionally, the benzene and toluene content, oxygenated compounds and the total oxygen content can be determined.
NOTE 1   For the purposes of this document, the terms % (m/m) and % (V/V) are used to represent respectively the mass fraction, w, and the volume fraction, φ.
This document defines two procedures, A and B.
Procedure A is applicable to automotive motor gasoline with total aromatics of 19,32 % (V/V) up to 46,29 % (V/V); total olefins from 0,40 % (V/V) up to 26,85 % (V/V); oxygenates from 0,61 % (V/V) up to 9,85 % (V/V); oxygen content from 1,50 % (m/m) to 12,32 % (m/m); benzene content from 0,38 % (V/V) up to 1,98 % (V/V) and toluene content from 5,85 % (V/V) up to 31,65 % (V/V).
The method has also been tested for individual oxygenates. A precision has been determined for a total volume of methanol from 1,05 % (V/V) up to 16,96 % (V/V); a total volume of ethanol from 0,50 % (V/V) up to 17,86 % (V/V); a total volume of MTBE from 0,99 % (V/V) up to 15,70 % (V/V), a total volume of ETBE from 0,99 % (V/V) up to 15,49 % (V/V), a total volume of TAME from 0,99 % (V/V) up to 5,92 % (V/V), and a total volume of TAEE from 0,98 % (V/V) up to 15,59 % (V/V).
Although this test method can be used to determine higher-olefin contents of up to 50 % (V/V), the precision for olefins was tested only in the range from 0,40 % (V/V) to 26,85 % (V/V).
Although specifically developed for the analysis of automotive motor gasoline that contains oxygenates, this test method can also be applied to other hydrocarbon streams having similar boiling ranges, such as naphthas and reformates.
NOTE 2   For Procedure A, applicability of this document has also been verified for the determination of n-propanol, acetone, and di-isopropyl ether (DIPE). However, no precision data have been determined for these compounds.
Procedure B describes the analysis of oxygenated groups (ethanol, methanol, ethers, C3 – C5 alcohols) in ethanol (E85) automotive fuel containing ethanol between 50 % (V/V) and 85 % (V/V). The gasoline is diluted with an oxygenate-free component to lower the ethanol content to a value below 20 % (V/V) before the analysis by GC.
The sample can be fully analysed including hydrocarbons. Precision data for the diluted sample are only available for the oxygenated groups.
NOTE 3   For Procedure B, the precision can be used for an ethanol fraction from about 50 % up to 85 % (V/V). For the ether fraction, the precision as specified in Table 6 can be used for samples containing at least 11 % (V/V) of ethers. For the higher alcohol fraction, too few data were obtained to derive a full precision statement and the data presented in Table 6 are therefore only indicative.
NOTE 4   An overlap between C9 and C10 aromatics can occur. However, the total is accurate. Isopropyl benzene is resolved from the C8 aromatics and is included with the other C9 aromatics.

  • Standard
    29 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    25 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies a fluorescent indicator adsorption method for the determination of hydrocarbon types over the concentration ranges from 5 % (V/V) to 99 % (V/V) aromatic hydrocarbons, 0,3 % (V/V) to 55 % (V/V) olefins, and 1 % (V/V) to 95 % (V/V) saturated hydrocarbons in petroleum fractions that distil below 315 ºC. This method may apply to concentrations outside these ranges, but the precision has not been determined.
When samples containing oxygenated blending components are analysed, the hydrocarbon type results can be reported on an oxygenate-free basis or, when the oxygenate content is known, the results can be corrected to a total-sample basis.
This test method is for use with full boiling range products. Cooperative data have established that the precision statement does not apply to petroleum fractions with narrow boiling ranges near the 315 °C limit. Such samples are not eluted properly, and results are erratic.
Samples containing dark-coloured components that interfere with reading the chromatographic bands cannot be analysed.
NOTE 1   The oxygenated blending components methanol, ethanol, tert-butyl methyl ether (MTBE), methyl tert-pentyl ether (TAME) and tert-butyl ethyl ether (ETBE) do not interfere with the determination of hydrocarbon types at concentrations normally found in commercial petroleum blends. These oxygenated compounds are not detected since they elute with the alcohol desorbent. The effects of other oxygenated compounds should be individually verified.
NOTE 2   For the purposes of this European Standard, the terms “% (m/m)” and “% (V/V)” are used to represent respectively the mass fraction and the volume fraction.
WARNING — The use of this European Standard may involve hazardous materials, operations and equipment. This European Standard does not purport to address all of the safety problems associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices

  • Standard
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the process and methodology for the construction, operation, and maintenance of statistical control charts to assess if a laboratory's execution of a standard test method is in-statistical-control and how to establish and validate the 'in-statistical-control' status. It specifies control charts that are most appropriate for ISO/TC 28 test methods where the dominant common cause variation is associated with the long term, multiple operator conditions. The control charts specified for determination of in-statistical-control are: individual (I), moving range of 2 (MR2), and either the exponentially weighted moving average (EWMA) or zone-based run rules [similar to Western Electric (WE) run rules[3]] as sensitivity enhancement strategy to support the I-chart. The procedures in this document have been primarily designed for numerical results obtained from testing of control samples prepared from a homogenous source of petroleum and related products in a manner that preserves the homogeneity of properties of interest between control samples. If the test method permits, a certified reference material (CRM) sample is used as a control sample provided the sample composition is representative of the material being tested and is not a pure compound; if this is done then the laboratory best establishes its own mean for the CRM sample. This document is applicable to properties of interest that are (known to be) stable over time, and for data sets with sufficient resolution to support validation of the assumption that the data distribution can be approximately represented by the normal (Gaussian) model. Mitigating strategies are suggested for situations where the assumption cannot be validated.

  • Standard
    36 pages
    English language
    sale 15% off
  • Standard
    38 pages
    French language
    sale 15% off
  • Draft
    36 pages
    English language
    sale 15% off
  • Draft
    36 pages
    French language
    sale 15% off

This document specifies a procedure, at temperatures up to 100 °C, to determine whether a liquid product, that would be classified as “flammable” by virtue of its flash point, sustains combustion at the temperature(s) specified e.g. in regulations.
NOTE       Many national and international regulations classify liquids as presenting a flammable hazard based on their flash point, as determined by a recognized method. Some of these regulations allow a derogation if the substance cannot “sustain combustion” at some specified temperature(s).
The procedure is applicable to paints (including water-borne paints), varnishes, paint binders, solvents, petroleum or related products and adhesives, that have a flash point. It is not applicable to painted surfaces in respect of assessing their potential fire hazards.
This test method is applicable, in addition to test methods for flash point, for assessing the fire hazard of a product.

  • Standard
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a method for the determination of the manual and automated closed cup flash point of combustible liquids having flash points between –30,0 °C to 75,0 °C. However, the precision given for this method is only valid for flash points in the range −8,5 °C to 75,0 °C.
This document is not applicable to water-borne paints.
NOTE 1   Water borne paints can be tested using ISO 3679[1].
NOTE 2   See 9.1 for the importance of this test in avoiding loss of volatile materials.
NOTE 3   Liquids containing halogenated compounds can give anomalous results.
NOTE 4   The thermometer specified for the manual apparatus limits the upper test temperature to 70,0 °C.
NOTE 5   See 13.1 for more specific information related to precision.

  • Standard
    32 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    30 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard describes a method for the determination of the boiling range distribution of petroleum products by capillary gas chromatography using flame ionization detection. The standard is applicable to stabilized crude oils and for the boiling range distribution and the recovery up to and including n-nonane. A stabilized crude oil is defined as having a Reid Vapour Pressure equivalent to or less than 82,7 kPa as determined by IP 481 [3].
NOTE   For the purposes of this European Standard, the terms “% (m/m)” and “% (V/V)” are used to represent respectively the mass fraction, ω, and the volume fraction, φ.
WARNING —The use of this European Standard may involve hazardous materials, operations and equipment. This European Standard does not purport to address all of the safety problems associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use.

  • Standard
    31 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    30 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    7 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    1 page
    English language
    sale 15% off
  • Standard
    1 page
    French language
    sale 15% off
  • Draft
    1 page
    English language
    sale 15% off
  • Draft
    1 page
    French language
    sale 15% off

This document specifies the gas chromatographic (GC) method for the determination of saturated, olefinic and aromatic hydrocarbons in automotive motor gasoline and ethanol (E85) automotive fuel. Additionally, the benzene and toluene content, oxygenated compounds and the total oxygen content can be determined. NOTE 1 For the purposes of this document, the terms % (m/m) and % (V/V) are used to represent respectively the mass fraction, w, and the volume fraction, φ. This document defines two procedures, A and B. Procedure A is applicable to automotive motor gasoline with total aromatics of 19,32 % (V/V) up to 46,29 % (V/V); total olefins from 0,40 % (V/V) up to 26,85 % (V/V); oxygenates from 0,61 % (V/V) up to 9,85 % (V/V); oxygen content from 1,50 % (m/m) to 12,32 % (m/m); benzene content from 0,38 % (V/V) up to 1,98 % (V/V) and toluene content from 5,85 % (V/V) up to 31,65 % (V/V). The method has also been tested for individual oxygenates. A precision has been determined for a total volume of methanol from 1,05 % (V/V) up to 16,96 % (V/V); a total volume of ethanol from 0,50 % (V/V) up to 17,86 % (V/V); a total volume of MTBE from 0,99 % (V/V) up to 15,70 % (V/V), a total volume of ETBE from 0,99 % (V/V) up to 15,49 % (V/V), a total volume of TAME from 0,99 % (V/V) up to 5,92 % (V/V), and a total volume of TAEE from 0,98 % (V/V) up to 15,59 % (V/V). Although this test method can be used to determine higher-olefin contents of up to 50 % (V/V), the precision for olefins was tested only in the range from 0,40 % (V/V) to 26,85 % (V/V). Although specifically developed for the analysis of automotive motor gasoline that contains oxygenates, this test method can also be applied to other hydrocarbon streams having similar boiling ranges, such as naphthas and reformates. NOTE 2 For Procedure A, applicability of this document has also been verified for the determination of n-propanol, acetone, and di-isopropyl ether (DIPE). However, no precision data have been determined for these compounds. Procedure B describes the analysis of oxygenated groups (ethanol, methanol, ethers, C3 – C5 alcohols) in ethanol (E85) automotive fuel containing ethanol between 50 % (V/V) and 85 % (V/V). The gasoline is diluted with an oxygenate-free component to lower the ethanol content to a value below 20 % (V/V) before the analysis by GC. The sample can be fully analysed including hydrocarbons. Precision data for the diluted sample are only available for the oxygenated groups. NOTE 3 For Procedure B, the precision can be used for an ethanol fraction from about 50 % up to 85 % (V/V). For the ether fraction, the precision as specified in Table 6 can be used for samples containing at least 11 % (V/V) of ethers. For the higher alcohol fraction, too few data were obtained to derive a full precision statement and the data presented in Table 6 are therefore only indicative. NOTE 4 An overlap between C9 and C10 aromatics can occur. However, the total is accurate. Isopropyl benzene is resolved from the C8 aromatics and is included with the other C9 aromatics.

  • Standard
    21 pages
    English language
    sale 15% off
  • Standard
    22 pages
    French language
    sale 15% off
  • Draft
    21 pages
    English language
    sale 15% off
  • Draft
    22 pages
    French language
    sale 15% off

This document specifies a method for the determination of the boiling range distribution of petroleum products by capillary gas chromatography using flame ionization detection. The standard is applicable to materials having a vapour pressure low enough to permit sampling at ambient temperature, and which have a boiling range of at least 100 °C. The standard is applicable to materials with initial boiling points (IBP) above 100 °C and final boiling points (FBP) above 750 °C, for example, heavy distillate fuels and residuals. The method is not applicable to bituminous samples.
The test method is not applicable for the analysis of petroleum or petroleum products containing low molecular weight components (for example naphthas, reformates, gasolines) or middle distillates like Diesel and Jet fuel.
Petroleum or petroleum products containing blending components, which contain hetero atoms (for example alcohols, ethers, acids, or esters) or residue, are not to be analysed by this test method.
NOTE For the purposes of this document, the terms "% (m/m)" and "% (V/V)" are used to represent respectively the mass fraction and the volume fraction.
WARNING - The use of this document may involve hazardous materials, operations and equipment. This document does not purport to address all of the safety problems associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use.

  • Standard
    29 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    28 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document describes a method for the determination of the boiling range distribution of petroleum products by capillary gas chromatography using flame ionization detection. The standard is applicable to crude oils. The boiling range distribution and recovery to C100 or C120 can be determined.
Two procedures are described: single and dual analysis mode. The basis of each is the calculation procedure as described in Annex A.
Procedure A (or Single analysis mode) determines the boiling range through C100 or C120 in a single analysis.
Procedure B (or Dual analysis mode) combines procedure A with the boiling point distribution from C1 up to C9 using the Detailed Hydrocarbon Analysis (DHA) according EN 15199-4. The results of both analyses are merged into one boiling point distribution.
NOTE 1 There is no specific precision statement for the combined results obtained by procedure B. For the precision of the boiling range distribution according to procedure B the precision statements of procedure A and EN 15199-4 apply. No precision has been determined for the results after merging.
NOTE 2 For the purpose of this document, the terms "% (m/m)" and "% (V/V)" are used to represent the mass fraction, μ, and the volume fraction, φ, of a material respectively.
WARNING - Use of this document may involve hazardous materials, operations and equipment. This document does not purport to address all of the safety problems associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use.

  • Standard
    39 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    38 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a method for the determination of the boiling range distribution of petroleum products by capillary gas chromatography using flame ionization detection. The standard is applicable to materials having a vapour pressure low enough to permit sampling at ambient temperature and a boiling range of at least 100 °C. The standard is applicable to distillates with initial boiling points (IBP) above 100 °C and final boiling points (FBP) below 750 °C, for example, middle distillates and lubricating base stocks.
The test method is not applicable for the analysis of petroleum or petroleum products containing low molecular weight components (for example naphtha’s, reformates, gasolines) or middle distillates like Diesel and Jet fuel.
Petroleum or petroleum products containing blending components which contain heteroatoms (for example alcohols, ethers, acids, or esters) or residue are not to be analysed by this test method.
NOTE For the purposes of this document, the terms "% (m/m)" and "% (V/V)" are used to represent respectively the mass fraction and the volume fraction.
WARNING - The use of this document can involve hazardous materials, operations and equipment. This document does not purport to address all of the safety problems associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use.

  • Standard
    26 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    26 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a method for the determination of the manual and automated closed cup flash
point of combustible liquids having flash points between –30,0 °C to 75,0 °C. However, the precision
given for this method is only valid for flash points in the range −8,5 °C to 75,0 °C.
This document is not applicable to water-borne paints.
NOTE 1 Water borne paints can be tested using ISO 3679[1].
NOTE 2 See 9.1 for the importance of this test in avoiding loss of volatile materials.
NOTE 3 Liquids containing halogenated compounds can give anomalous results.
NOTE 4 The thermometer specified for the manual apparatus limits the upper test temperature to 70,0 °C.
NOTE 5 See 13.1 for more specific information related to precision.

  • Standard
    32 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    30 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a procedure, at temperatures up to 100 °C, to determine whether a liquid product, that would be classified as “flammable” by virtue of its flash point, sustains combustion at the temperature(s) specified e.g. in regulations. NOTE Many national and international regulations classify liquids as presenting a flammable hazard based on their flash point, as determined by a recognized method. Some of these regulations allow a derogation if the substance cannot “sustain combustion” at some specified temperature(s). The procedure is applicable to paints (including water-borne paints), varnishes, paint binders, solvents, petroleum or related products and adhesives, that have a flash point. It is not applicable to painted surfaces in respect of assessing their potential fire hazards. This test method is applicable, in addition to test methods for flash point, for assessing the fire hazard of a product.

  • Standard
    12 pages
    English language
    sale 15% off
  • Standard
    13 pages
    French language
    sale 15% off
  • Draft
    12 pages
    English language
    sale 15% off
  • Draft
    14 pages
    French language
    sale 15% off
  • Amendment
    7 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a method for the determination of the manual and automated closed cup flash point of combustible liquids having flash points between –30,0 °C to 75,0 °C. However, the precision given for this method is only valid for flash points in the range −8,5 °C to 75,0 °C. This document is not applicable to water-borne paints. NOTE 1 Water borne paints can be tested using ISO 3679[1]. NOTE 2 See 9.1 for the importance of this test in avoiding loss of volatile materials. NOTE 3 Liquids containing halogenated compounds can give anomalous results. NOTE 4 The thermometer specified for the manual apparatus limits the upper test temperature to 70,0 °C. NOTE 5 See 13.1 for more specific information related to precision.

  • Standard
    24 pages
    English language
    sale 15% off
  • Standard
    26 pages
    French language
    sale 15% off
  • Draft
    24 pages
    English language
    sale 15% off
  • Draft
    29 pages
    French language
    sale 15% off

This document specifies Procedure A, using manual glass viscometers, and Procedure B, using glass capillary viscometers in an automated assembly, for the determination of the kinematic viscosity, ν, of liquid petroleum products, both transparent and opaque, by measuring the time for a volume of liquid to flow under gravity through a calibrated glass capillary viscometer. The dynamic viscosity, η, is obtained by multiplying the measured kinematic viscosity by the density, ρ, of the liquid. The range of kinematic viscosities covered in this test method is from 0,2 mm2/s to 300 000 mm2/s over the temperature range ?20 °C to +150 °C.
NOTE    The result obtained from this document is dependent upon the behaviour of the sample and is intended for application to liquids for which primarily the shear stress and shear rates are proportional (Newtonian flow behaviour). If, however, the viscosity varies significantly with the rate of shear, different results can be obtained from viscometers of different capillary diameters. The procedure and precision values for residual fuel oils, which under some conditions exhibit non-Newtonian behaviour, have been included.

  • Standard
    32 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    1 page
    English language
    sale 15% off
  • Standard
    1 page
    French language
    sale 15% off
  • Draft
    1 page
    English language
    sale 15% off

This European Standard specifies a method for the determination of the boiling range distribution of petroleum products by capillary gas chromatography using flame ionisation detection. The standard is applicable to materials having a vapour pressure low enough to permit sampling at ambient temperature, and which have a boiling range of at least 100 °C. The standard is applicable to materials with initial boiling points (IBP) above 100 °C and final boiling points (FBP) above 750 °C, for example, heavy distillate fuels and residuals. The method is not applicable to bituminous samples.
The test method is not applicable for the analysis of petroleum or petroleum products containing low molecular weight components (for example naphthas, reformates, gasolines, diesel). Components containing hetero atoms (for example alcohols, ethers, acids, or esters) or residue are not to be analyzed by this test method.
NOTE   For the purposes of this European Standard, the terms "% (m/m)" and "% (V/V)" are used to represent respectively the mass fraction and the volume fraction.
WARNING - The use of this European Standard may involve hazardous materials, operations and equipment. This European Standard does not purport to address all of the safety problems associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use.

  • Standard
    29 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    28 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies a method for the determination of the boiling range distribution of petroleum products by capillary gas chromatography using flame ionisation detection. The standard is applicable to materials having a vapour pressure low enough to permit sampling at ambient temperature and a boiling range of at least 100 °C. The standard is applicable to distillates with initial boiling points (IBP) above 100 °C and final boiling points (FBP) below 750 °C, for example, middle distillates and lubricating base stocks.
The test method is not applicable for the analysis of petroleum or petroleum products containing low molecular weight components (for example naphthas, reformates, gasolines, diesel). Components containing hetero atoms (for example alcohols, ethers, acids, or esters) or residue are not to be analyzed by this test method.
NOTE   For the purposes of this European Standard, the terms “% (m/m)” and “% (V/V)” are used to represent respectively the mass fraction and the volume fraction.
WARNING — The use of this European Standard may involve hazardous materials, operations and equipment. This European Standard does not purport to address all of the safety problems associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use.

  • Standard
    26 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    26 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    2 pages
    English language
    sale 15% off
  • Standard
    2 pages
    French language
    sale 15% off
  • Draft
    2 pages
    English language
    sale 15% off

This document specifies Procedure A, using manual glass viscometers, and Procedure B, using glass
capillary viscometers in an automated assembly, for the determination of the kinematic viscosity, ν,
of liquid petroleum products, both transparent and opaque, by measuring the time for a volume of
liquid to flow under gravity through a calibrated glass capillary viscometer. The dynamic viscosity, η,
is obtained by multiplying the measured kinematic viscosity by the density, ρ, of the liquid. The range
of kinematic viscosities covered in this test method is from 0,2 mm2/s to 300 000 mm2/s over the
temperature range –20 °C to +150 °C.
NOTE The result obtained from this document is dependent upon the behaviour of the sample and is intended
for application to liquids for which primarily the shear stress and shear rates are proportional (Newtonian flow
behaviour). If, however, the viscosity varies significantly with the rate of shear, different results can be obtained
from viscometers of different capillary diameters. The procedure and precision values for residual fuel oils,
which under some conditions exhibit non-Newtonian behaviour, have been included.

  • Standard
    32 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a method for the assessment of the persistence of a flame applied to the edge of a wick of non-flammable material immersed in fire-resistant fluid.
This test does not determine the behaviour of a spray of fire-resistant fluid.
NOTE   Such test methods are specified in ISO 15029-1 and ISO 15029-2.
This document specifies one of four basic tests for determining flammability.
This document does not apply to certain liquids such as HFAE and HFAS liquids.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies Procedure A, using manual glass viscometers, and Procedure B, using glass capillary viscometers in an automated assembly, for the determination of the kinematic viscosity, ν, of liquid petroleum products, both transparent and opaque, by measuring the time for a volume of liquid to flow under gravity through a calibrated glass capillary viscometer. The dynamic viscosity, η, is obtained by multiplying the measured kinematic viscosity by the density, ρ, of the liquid. The range of kinematic viscosities covered in this test method is from 0,2 mm2/s to 300 000 mm2/s over the temperature range ?20 °C to +150 °C. NOTE The result obtained from this document is dependent upon the behaviour of the sample and is intended for application to liquids for which primarily the shear stress and shear rates are proportional (Newtonian flow behaviour). If, however, the viscosity varies significantly with the rate of shear, different results can be obtained from viscometers of different capillary diameters. The procedure and precision values for residual fuel oils, which under some conditions exhibit non-Newtonian behaviour, have been included.

  • Standard
    24 pages
    English language
    sale 15% off
  • Standard
    25 pages
    French language
    sale 15% off
  • Standard
    25 pages
    French language
    sale 15% off
  • Draft
    24 pages
    English language
    sale 15% off

This document specifies the methodology for the regular monitoring of the test method precision achieved versus the precision published in the standard test method using data from proficiency testing schemes (PTSs) supported by the regular users of standard test methods.
The procedures in this document are designed specifically for proficiency testing (PT) conducted on standard test methods, having a published reproducibility, for petroleum and petroleum-related products, which are presumed to be homogeneous, and where the data distribution is approximately normal. In addition, it is applicable to properties of interest that are (known to be) stable over time and transport.
This document specifies the methodology for the statistical comparison of standard deviation under reproducibility conditions achieved in PT programmes versus that published.
The purpose of this comparison is to find out if the published reproducibility precision is representative of that achievable by the regular participants in the PT programmes.
This document also provides guidance on how to use a PT z-score to monitor an individual participant's performance over time (see Annex B).

  • Standard
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a procedure for the determination of kinematic viscosity (ν) at 40 °C in the range from 2 mm2/s to 6 mm2/s by calculation from dynamic viscosity (η) and density (ρ) of middle distillate fuels, fatty acid methyl ester fuels (FAME) and mixtures of these using the Stabinger type viscometer. The result obtained using the procedure described in this document depends on the rheological behaviour of the sample. This document is predominantly applicable to liquids whose shear stress and shear rate are proportional (Newtonian flow behaviour). However, if the viscosity changes significantly with the shear rate, comparison with other measuring methods is only permissible at similar shear rates.

  • Standard
    9 pages
    English language
    sale 15% off
  • Draft
    9 pages
    English language
    sale 15% off

This document establishes an overview of test methods in the field to determine flash point and combustibility of petroleum and related products. It presents advice on application and specification development. This document is not intended to be a comprehensive manual on flash point and combustibility tests, and the interpretation of test results, however it covers the key aspects on these subjects.

  • Technical report
    15 pages
    English language
    sale 15% off
  • Technical report
    15 pages
    English language
    sale 15% off

ISO  14935 specifies a method for the assessment of the persistence of a flame applied to the edge of a wick of non-flammable material immersed in fire-resistant fluid.This test does not determine the behaviour of a spray of fire-resistant fluid.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the methodology for the design of an Interlaboratory Study (ILS) and
calculation of precision estimates of a test method specified by the study. In particular, it defines the
relevant statistical terms (Clause 3), the procedures to be adopted in the planning of ILS to determine
the precision of a test method (Clause 4), and the method of calculating the precision from the results of
such a study (Clauses 5 and 6).
The procedures in this document have been designed specifically for petroleum and petroleum related
products, which are normally considered as homogeneous. However, the procedures described in this
document can also be applied to other types of homogeneous products. Careful investigations are
necessary before applying this document to products for which the assumption of homogeneity can be
questioned.

  • Amendment
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    7 pages
    English language
    sale 10% off
    e-Library read for
    1 day