Rigid cellular plastics - Spray-applied polyurethane foam for thermal insulation - Part 1: Material specifications

This part of ISO 8873 specifies minimum requirements and test methods for spray-applied polyurethane rigid
cellular plastic, used as a thermal insulation for both building, whether applied on a building site or in a
prefabrication (manufacturing) facility, and non-building applications. The material is also known as in-situ
thermal insulation.
The spray-applied polyurethane rigid cellular plastic thermal insulation is not to be used when the continuous
service temperature of the substrate is outside the range of to .
The test methods used to determine the material properties provide a means of comparing different cellular
plastic thermal insulations. They are intended for use in specifications, product evaluations and quality control.
They are not intended to predict end-use product performance.
Spray-applied polyurethane rigid cellular plastics are to be applied (installed) in accordance with the
manufacturer's instructions and the requirements of ISO 8873-2. Applications, requirements for applications
and limitations of use are included in ISO 8873-2.

Plastiques alvéolaires rigides - Mousse de polyuréthanne projetée pour l'isolation thermique - Partie 1: Spécifications des matériaux

Penjeni polimerni materiali - Brizgana poliuretanska pena za toplotno izolacijo - 1. del: Specifikacije materiala

Ta del standarda ISO 8873 določa minimalne zahteve in metode preskušanja za brizgano poliuretansko peno iz penjenega polimernega materiala, ki se uporablja kot toplotna izolacija v stavbah, ne glede na to, ali se uporablja na gradbišču ali v montažnem (proizvodnem) obratu, ali zunaj stavb. Material se imenuje tudi toplotna izolacija, izdelana na kraju samem.
Toplotna izolacija iz brizgane poliuretanske pene iz penjenega polimernega materiala se ne sme uporabljati, če je razpon stalne delovne temperature podlage zunaj območja do .
Metode preskušanja, uporabljene za določanje lastnosti materialov, zagotavljajo način za primerjavo različne toplotne izolacije iz brizgane poliuretanske pene. Namenjene so za uporabo pri specifikacijah, vrednotenju proizvodov in kontroli kakovosti.
Niso namenjene za napovedovanje lastnosti končnega proizvoda.
Brizgana poliuretanska pena iz penjenega polimernega materiala se mora uporabljati (namestiti) v skladu z
navodili proizvajalca in zahtevami iz standarda ISO 8873-2. Uporabe, zahteve za uporabo in omejitve uporabe so vključene v standard ISO 8873-2.

General Information

Status
Published
Publication Date
04-Feb-2015
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
27-Jan-2015
Due Date
03-Apr-2015
Completion Date
05-Feb-2015

Relations

Buy Standard

Standard
ISO 8873-1:2006 - Rigid cellular plastics -- Spray-applied polyurethane foam for thermal insulation
English language
9 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
ISO 8873-1:2015
English language
14 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

INTERNATIONAL ISO
STANDARD 8873-1
First edition
2006-12-15
Rigid cellular plastics — Spray-applied
polyurethane foam for thermal
insulation —
Part 1:
Material specifications
Plastiques alvéolaires rigides — Mousse de polyuréthanne projetée
pour l'isolation thermique —
Partie 1: Spécifications des matériaux

Reference number
ISO 8873-1:2006(E)
©
ISO 2006

---------------------- Page: 1 ----------------------
ISO 8873-1:2006(E)
PDF disclaimer
This PDF file may contain embedded typefaces. In accordance with Adobe's licensing policy, this file may be printed or viewed but shall
not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In
downloading this file, parties accept therein the responsibility of not infringing Adobe's licensing policy. The ISO Central Secretariat
accepts no liability in this area.
Adobe is a trademark of Adobe Systems Incorporated.
Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation
parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In the
unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below.
© ISO 2006
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means,
electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or
ISO's member body in the country of the requester.
ISO copyright office
Case postale 56  CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland
©
ii ISO 2006 – All rights reserved

---------------------- Page: 2 ----------------------
ISO 8873-1:2006(E)
Contents Page
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 2
4 Requirements . 3
4.1 General requirements . 3
4.2 Categories . 3
5 Sampling . 4
5.1 General . 4
5.2 Preparation of sample panels . 4
5.3 Conditioning of sample panels . 4
5.4 Preparation of specimens . 4
6 Test methods . 5
6.1 Air permeance . 5
6.2 Apparent core density . 5
6.3 Compressive strength . 5
6.4 Dimensional stability . 5
6.5 Surface burning characteristics . 5
6.6 Open-cell content: Volume . 5
6.7 Initial thermal resistance . 5
6.8 Long-term thermal resistance (LTTR) . 6
6.9 Tensile strength . 6
6.10 Substrate adhesion . 7
6.11 Volatile organic emissions . 7
6.12 Water absorption . 7
6.13 Water vapour permeability . 7
7 Reporting requirements . 7
8 Marking, labelling and packaging . 8
8.1 Packaging . 8
8.2 Marking and/or labelling . 8
9 Manufacturer's documentation . 8
©
ISO 2006 – All rights reserved iii

---------------------- Page: 3 ----------------------
ISO 8873-1:2006(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies
(ISO member bodies). The work of preparing International Standards is normally carried out through ISO
technical committees. Each member body interested in a subject for which a technical committee has been
established has the right to be represented on that committee. International organizations, governmental and
non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International
Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.
The main task of technical committees is to prepare International Standards. Draft International Standards
adopted by the technical committees are circulated to the member bodies for voting. Publication as an
International Standard requires approval by at least 75 % of the member bodies casting a vote.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. ISO shall not be held responsible for identifying any or all such patent rights.
ISO 8873-1 was prepared by Technical Committee ISO/TC 61, Plastics, Subcommittee SC 10, Cellular plastics.
This first edition of ISO8873-1, together with ISO8873-2 and ISO8873-3, cancels and replaces
ISO 8873:1987, which has been technically revised.
ISO8873 consists of the following parts, under the general title Rigid cellular plastics— Spray-applied
polyurethane foam for thermal insulation:
— Part 1: Material specifications
— Part 2: Application
— Part 3: Test methods
©
iv ISO 2006 – All rights reserved

---------------------- Page: 4 ----------------------
ISO 8873-1:2006(E)
Introduction
ISO 8873 defines the requirements for rigid cellular plastic spray polyurethane foam when used as a thermal
insulation in buildings and non-buildings.
This part of ISO8873 specifies requirements for the physical properties of rigid cellular plastic spray
polyurethane foam and lists the test methods to be used.
The designer has the responsibility for confirming that the physical properties provided by material
manufactured to this part of ISO 8873 will conform to the requirements for a specific application.
©
ISO 2006 – All rights reserved v

---------------------- Page: 5 ----------------------
.
vi

---------------------- Page: 6 ----------------------
INTERNATIONAL STANDARD ISO 8873-1:2006(E)
Rigid cellular plastics — Spray-applied polyurethane foam for
thermal insulation —
Part 1:
Material specifications
WARNING—Persons using this document should be familiar with normal laboratory practice, if
applicable. This document does not purport to address all of the safety concerns, if any, associated
with its use. It is the responsibility of the user to establish appropriate safety and health practices and
to ensure compliance with any regulatory requirements.
1Scope
This part of ISO 8873 specifies minimum requirements and test methods for spray-applied polyurethane rigid
cellular plastic, used as a thermal insulation for both building, whether applied on a building site or in a
prefabrication (manufacturing) facility, and non-building applications. The material is also known as in-situ
thermal insulation.
The spray-applied polyurethane rigid cellular plastic thermal insulation is not to be used when the continuous
◦ ◦
service temperature of the substrate is outside the range of −60 C to +80 C.
The test methods used to determine the material properties provide a means of comparing different cellular
plastic thermal insulations. They are intended for use in specifications, product evaluations and quality control.
They are not intended to predict end-use product performance.
Spray-applied polyurethane rigid cellular plastics are to be applied (installed) in accordance with the
manufacturer's instructions and the requirements of ISO 8873-2. Applications, requirements for applications
and limitations of use are included in ISO 8873-2.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced document
(including any amendments) applies.
ISO 291, Plastics — Standard atmospheres for conditioning and testing
ISO 844, Rigid cellular plastics — Determination of compression properties
ISO 845, Cellular plastics and rubbers — Determination of apparent density
ISO 1663, Rigid cellular plastics — Determination of water vapour transmission properties
ISO 1926, Rigid cellular plastics — Determination of tensile properties
ISO 2796, Cellular plastics, rigid — Test for dimensional stability
ISO 2896, Rigid cellular plastics — Determination of water absorption
©
ISO 2006 – All rights reserved 1

---------------------- Page: 7 ----------------------
ISO 8873-1:2006(E)
ISO 4590, Rigid cellular plastics — Determination of the volume percentage of open cells and of closed cells
ISO 8301, Thermal insulation — Determination of steady-state thermal resistance and related properties —
Heat flow meter apparatus
ISO 8302, Thermal insulation — Determination of steady-state thermal resistance and related properties —
Guarded hot plate apparatus
1)
ISO 8873-2:— , Rigid cellular plastics — Spray-applied polyurethane foam for thermal insulation — Part 2:
Application
2)
ISO 8873-3:— , Rigid cellular plastics — Spray-applied polyurethane foam for thermal insulation — Part 3:
Test methods
ISO 10456, Building materials and products— Hygrothermal properties— Tabulated design values and
procedures for determining declared and design thermal values
ISO 11561, Ageing of thermal insulation materials — Determination of the long-term change in thermal
resistance of closed-cell plastics (accelerated laboratory test methods)
ISO/IEC 17024, Conformity assessment — General requirements for bodies operating certification of persons
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1
authority having jurisdiction
officer or officers having authority, under appropriate regulatory instruments, to exercise enforcement
3.2
certification organization
impartial body possessing the necessary competence and reliability to operate a certification system in
accordance with ISO/IEC 17024, in which the interests of all parties concerned with the functioning of the
system are represented
3.3
equipment manufacturer
manufacturer of equipment designed for spray-application of rigid polyurethane cellular plastic thermal
insulation
3.4
in-situ thermal insulation
thermal insulation product produced or taking its final form at the site of application and which achieves its
properties after installation
3.5
spray-applied polyurethane foam
rigid cellular plastic material with substantially closed cell structure based on polyurethanes, which is foamed in-
situ by the catalysed reaction of polyisocyanates and polyhydroxyl compounds, expanded with blowing agents
3.6
spray polyurethane foam contractor
individual, organization or corporation who is responsible for all requirements and obligations for the installation
of the product
1) To be published.
2) To be published.
©
2 ISO 2006 – All rights reserved

---------------------- Page: 8 ----------------------
ISO 8873-1:2006(E)
3.7
spray polyurethane foam installer
individual or worker who applies the chemical components by mixing and spraying them to form the rigid cellular
plastic spray polyurethane foam product
NOTE The installer is responsible for the actual installation and site requirements identified by the manufacturer and/or
ISO 8873-2 for application of the product. The installer shall be trained, and qualified as having demonstrated the required
knowledge for proper application of the product by a Certification Organization (CO). The installer shall follow the
requirements for installation and the obligations for installers identified by the manufacturer and ISO 8873-2.
3.8
spray polyurethane foam system manufacturer
manufacturer/supplier of the liquid chemical components, polyisocyanates and a polyhydroxyl blends containing
also flame retardants, blowing agent and catalysts (system), which are designed to be mixed and sprayed to
form rigid polyurethane foam insulation material in situ
4 Requirements
4.1 General requirements
Rigid cellular plastic spray-applied polyurethane foam thermal insulation shall be applied by a spray
polyurethane foam contractor using a spray polyurethane foam installer in accordance with ISO 8873-2 and the
instructions given by the chemical manufacturer.
When applied, the polyurethane rigid cellular plastic thermal insulation shall not present a health hazard to the
potential occupants nor shall the cured insulation have any residual odour.
Special applications may require properties other than, or in addition to, those specified in this part of ISO 8873.
These properties, when agreed upon by the interested parties, may be added to the requirements of this
specification.
When stored in accordance with the chemical manufacturer's instructions, applied in accordance with
ISO8873-2, and within the shelf life of the chemicals as declared by the manufacturer, the chemical
components shall produce an insulation that meets the requirements of this part of ISO 8873.
4.2 Categories
Category IA: Suitable for non-load-bearing insulations that may not be exposed to weather, such as wall
insulations, interior roof insulations and similar applications where the insulation is only required to be self-
supporting, expanded with fluorocarbons and producing a predominantly closed-cell product.
Category IB: Suitable for non-load-bearing insulations that may not be exposed to weather, such as wall
insulations, interior roof insulations and similar applications where the insulation is only required to be
...

SLOVENSKI STANDARD
SIST ISO 8873-1:2015
01-marec-2015
Penjeni polimerni materiali - Brizgana poliuretanska pena za toplotno izolacijo - 1.
del: Specifikacije materiala
Rigid cellular plastics - Spray-applied polyurethane foam for thermal insulation - Part 1:
Material specifications
Plastiques alvéolaires rigides - Mousse de polyuréthanne projetée pour l'isolation
thermique - Partie 1: Spécifications des matériaux
Ta slovenski standard je istoveten z: ISO 8873-1:2006
ICS:
83.100 Penjeni polimeri Cellular materials
SIST ISO 8873-1:2015 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST ISO 8873-1:2015

---------------------- Page: 2 ----------------------

SIST ISO 8873-1:2015
INTERNATIONAL ISO
STANDARD 8873-1
First edition
2006-12-15
Rigid cellular plastics — Spray-applied
polyurethane foam for thermal
insulation —
Part 1:
Material specifications
Plastiques alvéolaires rigides — Mousse de polyuréthanne projetée
pour l'isolation thermique —
Partie 1: Spécifications des matériaux

Reference number
ISO 8873-1:2006(E)
©
ISO 2006

---------------------- Page: 3 ----------------------

SIST ISO 8873-1:2015
ISO 8873-1:2006(E)
PDF disclaimer
This PDF file may contain embedded typefaces. In accordance with Adobe's licensing policy, this file may be printed or viewed but shall
not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In
downloading this file, parties accept therein the responsibility of not infringing Adobe's licensing policy. The ISO Central Secretariat
accepts no liability in this area.
Adobe is a trademark of Adobe Systems Incorporated.
Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation
parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In the
unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below.
© ISO 2006
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means,
electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or
ISO's member body in the country of the requester.
ISO copyright office
Case postale 56  CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland
©
ii ISO 2006 – All rights reserved

---------------------- Page: 4 ----------------------

SIST ISO 8873-1:2015
ISO 8873-1:2006(E)
Contents Page
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 2
4 Requirements . 3
4.1 General requirements . 3
4.2 Categories . 3
5 Sampling . 4
5.1 General . 4
5.2 Preparation of sample panels . 4
5.3 Conditioning of sample panels . 4
5.4 Preparation of specimens . 4
6 Test methods . 5
6.1 Air permeance . 5
6.2 Apparent core density . 5
6.3 Compressive strength . 5
6.4 Dimensional stability . 5
6.5 Surface burning characteristics . 5
6.6 Open-cell content: Volume . 5
6.7 Initial thermal resistance . 5
6.8 Long-term thermal resistance (LTTR) . 6
6.9 Tensile strength . 6
6.10 Substrate adhesion . 7
6.11 Volatile organic emissions . 7
6.12 Water absorption . 7
6.13 Water vapour permeability . 7
7 Reporting requirements . 7
8 Marking, labelling and packaging . 8
8.1 Packaging . 8
8.2 Marking and/or labelling . 8
9 Manufacturer's documentation . 8
©
ISO 2006 – All rights reserved iii

---------------------- Page: 5 ----------------------

SIST ISO 8873-1:2015
ISO 8873-1:2006(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies
(ISO member bodies). The work of preparing International Standards is normally carried out through ISO
technical committees. Each member body interested in a subject for which a technical committee has been
established has the right to be represented on that committee. International organizations, governmental and
non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International
Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.
The main task of technical committees is to prepare International Standards. Draft International Standards
adopted by the technical committees are circulated to the member bodies for voting. Publication as an
International Standard requires approval by at least 75 % of the member bodies casting a vote.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. ISO shall not be held responsible for identifying any or all such patent rights.
ISO 8873-1 was prepared by Technical Committee ISO/TC 61, Plastics, Subcommittee SC 10, Cellular plastics.
This first edition of ISO8873-1, together with ISO8873-2 and ISO8873-3, cancels and replaces
ISO 8873:1987, which has been technically revised.
ISO8873 consists of the following parts, under the general title Rigid cellular plastics— Spray-applied
polyurethane foam for thermal insulation:
— Part 1: Material specifications
— Part 2: Application
— Part 3: Test methods
©
iv ISO 2006 – All rights reserved

---------------------- Page: 6 ----------------------

SIST ISO 8873-1:2015
ISO 8873-1:2006(E)
Introduction
ISO 8873 defines the requirements for rigid cellular plastic spray polyurethane foam when used as a thermal
insulation in buildings and non-buildings.
This part of ISO8873 specifies requirements for the physical properties of rigid cellular plastic spray
polyurethane foam and lists the test methods to be used.
The designer has the responsibility for confirming that the physical properties provided by material
manufactured to this part of ISO 8873 will conform to the requirements for a specific application.
©
ISO 2006 – All rights reserved v

---------------------- Page: 7 ----------------------

SIST ISO 8873-1:2015
.
vi

---------------------- Page: 8 ----------------------

SIST ISO 8873-1:2015
INTERNATIONAL STANDARD ISO 8873-1:2006(E)
Rigid cellular plastics — Spray-applied polyurethane foam for
thermal insulation —
Part 1:
Material specifications
WARNING—Persons using this document should be familiar with normal laboratory practice, if
applicable. This document does not purport to address all of the safety concerns, if any, associated
with its use. It is the responsibility of the user to establish appropriate safety and health practices and
to ensure compliance with any regulatory requirements.
1Scope
This part of ISO 8873 specifies minimum requirements and test methods for spray-applied polyurethane rigid
cellular plastic, used as a thermal insulation for both building, whether applied on a building site or in a
prefabrication (manufacturing) facility, and non-building applications. The material is also known as in-situ
thermal insulation.
The spray-applied polyurethane rigid cellular plastic thermal insulation is not to be used when the continuous
◦ ◦
service temperature of the substrate is outside the range of −60 C to +80 C.
The test methods used to determine the material properties provide a means of comparing different cellular
plastic thermal insulations. They are intended for use in specifications, product evaluations and quality control.
They are not intended to predict end-use product performance.
Spray-applied polyurethane rigid cellular plastics are to be applied (installed) in accordance with the
manufacturer's instructions and the requirements of ISO 8873-2. Applications, requirements for applications
and limitations of use are included in ISO 8873-2.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced document
(including any amendments) applies.
ISO 291, Plastics — Standard atmospheres for conditioning and testing
ISO 844, Rigid cellular plastics — Determination of compression properties
ISO 845, Cellular plastics and rubbers — Determination of apparent density
ISO 1663, Rigid cellular plastics — Determination of water vapour transmission properties
ISO 1926, Rigid cellular plastics — Determination of tensile properties
ISO 2796, Cellular plastics, rigid — Test for dimensional stability
ISO 2896, Rigid cellular plastics — Determination of water absorption
©
ISO 2006 – All rights reserved 1

---------------------- Page: 9 ----------------------

SIST ISO 8873-1:2015
ISO 8873-1:2006(E)
ISO 4590, Rigid cellular plastics — Determination of the volume percentage of open cells and of closed cells
ISO 8301, Thermal insulation — Determination of steady-state thermal resistance and related properties —
Heat flow meter apparatus
ISO 8302, Thermal insulation — Determination of steady-state thermal resistance and related properties —
Guarded hot plate apparatus
1)
ISO 8873-2:— , Rigid cellular plastics — Spray-applied polyurethane foam for thermal insulation — Part 2:
Application
2)
ISO 8873-3:— , Rigid cellular plastics — Spray-applied polyurethane foam for thermal insulation — Part 3:
Test methods
ISO 10456, Building materials and products— Hygrothermal properties— Tabulated design values and
procedures for determining declared and design thermal values
ISO 11561, Ageing of thermal insulation materials — Determination of the long-term change in thermal
resistance of closed-cell plastics (accelerated laboratory test methods)
ISO/IEC 17024, Conformity assessment — General requirements for bodies operating certification of persons
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1
authority having jurisdiction
officer or officers having authority, under appropriate regulatory instruments, to exercise enforcement
3.2
certification organization
impartial body possessing the necessary competence and reliability to operate a certification system in
accordance with ISO/IEC 17024, in which the interests of all parties concerned with the functioning of the
system are represented
3.3
equipment manufacturer
manufacturer of equipment designed for spray-application of rigid polyurethane cellular plastic thermal
insulation
3.4
in-situ thermal insulation
thermal insulation product produced or taking its final form at the site of application and which achieves its
properties after installation
3.5
spray-applied polyurethane foam
rigid cellular plastic material with substantially closed cell structure based on polyurethanes, which is foamed in-
situ by the catalysed reaction of polyisocyanates and polyhydroxyl compounds, expanded with blowing agents
3.6
spray polyurethane foam contractor
individual, organization or corporation who is responsible for all requirements and obligations for the installation
of the product
1) To be published.
2) To be published.
©
2 ISO 2006 – All rights reserved

---------------------- Page: 10 ----------------------

SIST ISO 8873-1:2015
ISO 8873-1:2006(E)
3.7
spray polyurethane foam installer
individual or worker who applies the chemical components by mixing and spraying them to form the rigid cellular
plastic spray polyurethane foam product
NOTE The installer is responsible for the actual installation and site requirements identified by the manufacturer and/or
ISO 8873-2 for application of the product. The installer shall be trained, and qualified as having demonstrated the required
knowledge for proper application of the product by a Certification Organization (CO). The installer shall follow the
requirements for installation and the obligations for installers identified by the manufacturer and ISO 8873-2.
3.8
spray polyurethane foam system manufacturer
manufacturer/supplier of the liquid chemical components, polyisocyanates and a polyhydroxyl blends containing
also flame retardants, blowing agent and catalysts (system), which are designed to be mixed and sprayed to
form rigid polyurethane foam insulation material in situ
4 Requirements
4.1 General requirements
Rigid cellular plastic spray-applied polyurethane foam thermal insulation shall be applied by a spray
polyurethane foam contractor using a spray polyurethane foam installer in accordance with ISO 8873-2 and the
instructions given by the chemical manufacturer.
When applied, the polyurethane rigid cellular plastic thermal insulation shall not present a health hazard to the
potential occupants nor shall the cured insulation have any residual odour.
Special applications may require properties other than, or in addition to, those specified in this part of ISO 8873.
These properties, when agreed upon by the interested parties, may be added to the requirements of this
specification.
When stored in accordance with the chemical manufacturer's instructions, applied in accordance with
ISO8873-2, and within the shelf life of the chemicals as declared by the manufacturer, the chemical
components shall produce an insulation that meets the requirements of this part of ISO 8873.
4.2 Categories
Category IA: Suit
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.