This document specifies the necessary system hardware components, the characteristics, the component requirements and conditions for the application of robotic ultrasonic test systems. This document specifies the general requirements and acceptance criteria for robotic ultrasonic test systems. This document is applicable to robotic ultrasonic test systems composed of one or more robot(s). Some of the characteristics of a robot ultrasonic testing system can be application-specific. This document is applicable to conventional straight-beam probes and immersion technique. This document is also applicable for phased array equipment, but additional tests can be necessary.

  • Standard
    34 pages
    English language
    sale 15% off

This document specifies the requirements for the dimensions, material, manufacture and methods of use for calibration block No. 2 for setting and checking ultrasonic test equipment.

  • Standard
    9 pages
    English language
    sale 15% off
  • Standard
    9 pages
    French language
    sale 15% off
  • Standard
    9 pages
    French language
    sale 15% off

This document specifies the functional characteristics of multi-channel ultrasonic phased array instruments used for array probes and provides methods for their measurement and verification. This document is also applicable to ultrasonic phased array instruments in automated systems; but other tests can be needed to ensure satisfactory performance. When the phased array instrument is a part of an automated system, the acceptance criteria can be modified by agreement between the parties involved. This document also can partly be applicable to FMC instruments and TFM instruments. This document gives the extent of the verification and defines acceptance criteria within a frequency range of 0,5 MHz to 10 MHz.

  • Standard
    47 pages
    English language
    sale 15% off
  • Standard
    49 pages
    French language
    sale 15% off

This document specifies methods, tolerances and acceptance criteria for verifying the performance of combined ultrasonic test equipment (i.e. instrument, probes and cables connected) by the use of appropriate standard calibration blocks. These methods are specifically intended for manual test equipment, i.e. ultrasonic instruments according to ISO 22232-1, and for manual ultrasonic non-destructive testing with single- or dual-transducer probes according to ISO 22232-2. This document is also applicable for multi-channel instruments. For automated test equipment, different tests can be needed to ensure satisfactory performance. The specified methods are intended for the use by operators working under site or shop floor conditions. These methods are not intended to prove the suitability of the equipment for particular applications. This document excludes ultrasonic instruments for continuous waves. This document also excludes ultrasonic phased array systems, see e. g. ISO 18563-3. If a phased array instrument is used in combination with single- or dual-transducer probes, this document is applicable to this combination.

  • Standard
    10 pages
    English language
    sale 15% off
  • Standard
    11 pages
    French language
    sale 15% off

This document specifies the characteristics of probes used for non-destructive ultrasonic testing in the following categories with centre frequencies in the range of 0,5 MHz to 15 MHz, focusing or without focusing means: a) single- or dual-transducer contact probes generating longitudinal and/or transverse waves; b) single-transducer immersion probes. Where material-dependent ultrasonic values are specified in this document they are based on steels having a sound velocity of (5 920 ± 50) m/s for longitudinal waves, and (3 255 ± 30) m/s for transverse waves. This document excludes periodic tests for probes. Routine tests for the verification of probes using on-site procedures are given in ISO 22232-3. If parameters in addition to those specified in ISO 22232-3 are to be verified during the probe's life time, as agreed upon by the contracting parties, the procedures of verification for these additional parameters can be selected from those given in this document. This document also excludes ultrasonic phased array probes, therefore see ISO 18563-2.

  • Standard
    56 pages
    English language
    sale 15% off
  • Standard
    56 pages
    French language
    sale 15% off

This document specifies methods and acceptance criteria within the frequency range of 0,5 MHz to 15 MHz, for assessing the electrical performance of digital ultrasonic instruments for pulse operation using A-scan display, for manual ultrasonic non-destructive testing with single- or dual-transducer probes. This document is also applicable for multi-channel instruments. This document can partly be applicable to ultrasonic instruments in automated systems, but other tests can be needed to ensure satisfactory performance. This document excludes ultrasonic instruments for continuous waves. This document also excludes ultrasonic phased array instruments, see e.g. ISO 18563-1. If a phased array instrument has dedicated connectors for single- or dual-transducer probes this document is applicable for these channels.

  • Standard
    40 pages
    English language
    sale 15% off
  • Standard
    42 pages
    French language
    sale 15% off